DATA CENTER
Energy reduction, operational efficiency, and OT/IT security at every scale.
From enterprise and colocation to hyperscale and edge — predictive cooling, AI orchestration, and hardened control systems.
AI-driven optimization & cyber-physical control — Santa Clara, 13 MW

22%
less energy
$2.3M
annual savings
99.995%
uptime
Read the full case study
Across 33,000+ racks and 150,000 VMs, edge telemetry, predictive ML, and dynamic HVAC optimization drove thermal efficiency and power distribution. Real-time PUE analytics, automated chiller sequencing, and adaptive CRAC modulation kept SLAs intact.
A compute-pod-first rollout closed the AI feedback loop across UPS, PDU, and rack-level monitoring; server utilization rose 12%.
Hybrid cloud enablement — financial services, Singapore, 10.5 MW

70%
faster VM provisioning
$4.5M
annual savings
99.99%
uptime
Read the full case study
Private VMware and OpenStack clusters were integrated with hyperscale public cloud for low-latency transactional workloads under MAS and PCI DSS compliance.
AI workload orchestration, capacity forecasting, and cross-platform CI/CD across 11,500+ VMs and 1,500+ hosts lifted utilization 25%. Migration progressed from non-critical to mission-critical workloads with automated DR orchestration.
Network security hardening — colocation, Europe

45%
lower breach risk
40%
faster detection
99.998%
uptime
Read the full case study
12,000+ endpoints, 2,250+ racks, and 1,200+ tenant environments were secured with AI anomaly detection, micro-segmented VLANs, next-gen firewalls, and SOAR remediation at OT/IT convergence points.
Full ISO 27001 and GDPR compliance was achieved through a risk-prioritized rollout integrating SIEM with firewall, tap, and endpoint telemetry.
Edge data center optimization — telecom, Asia

30%
faster response
$5M
annual savings
99.995%
availability
Read the full case study
6,600+ edge sites were modernized for 5G and IoT with AI orchestration of compute, storage, and network slices, automated failover, and SD-WAN optimization. Edge compute efficiency rose 18%.
Rollout began with high-traffic urban nodes and scaled to regional sites using containerized microservices and predictive resource scaling.
AI-powered cooling optimization — New York, 12.5 MW

1.6 → 1.33
PUE
20%
less cooling energy
99.996%
uptime
Read the full case study
Across 2,500+ racks and 420,000 virtualized workloads, real-time thermal mapping, ML airflow prediction, and automated CRAC modulation were integrated with BMS controls, lifting server utilization 15%.
Predictive AI workload balancing — hyperscale, Ireland

35%
fewer VM starvation events
$3.8M
annual savings
99.997%
SLA uptime
Read the full case study
Reinforcement-learning models and real-time telemetry across 53,500+ servers and 200,000 VMs improved utilization 20% and cut energy 12%, integrated with automated orchestration frameworks.
Zero trust & segmentation — data center campus, Germany

50%
lower lateral-movement risk
38%
faster MTTD
99.998%
uptime
Read the full case study
3,000+ endpoints and 1,000+ servers received AI-driven access control, micro-segmentation, and automated threat detection with SIEM integration and behavioral monitoring — full ISO 27001 and GDPR compliance.
Energy & controls system — 40 MW, Central Oregon

99.999%
availability at go-live
15–20%
PUE optimization
0
critical defects
Read the full case study
Two data halls with a centralized energy plant were delivered on a 14-month schedule within a $150M capital envelope. A cause-and-effect matrix governed 3,000–5,000 I/O points across chilled water, CRAH, MV distribution, UPS, and 60–90 MW standby generation (N+1 / 2N).
800+ operational and fault-response sequences enabled deterministic behavior and sub-second failover, validated through multi-stage integrated systems testing to Tier III concurrent maintainability. SCADA/BMS platforms now analyze 100M+ data points a year for FDD and predictive maintenance.
AI energy & workload optimization — colocation, Australia, 3 MW

24%
less energy
~$2.8M
annual savings
99.996%
uptime
Read the full case study
Predictive analytics for workload distribution, automated cooling management, and PDU-level monitoring across 2,800+ racks and 140,000 VMs, integrated with DCIM dashboards and closed-loop control. Utilization rose 14%.
OT risk assessment — Tier III data center

IEC 62443
+ NIST CSF aligned
ISO 27001
audit-ready
Read the full case study
BMS and OT networks controlling HVAC, power, and fire suppression were assessed via asset inventory, network mapping, and threat modeling. Exposed controllers, weak authentication, and insufficient monitoring were found.
Segmentation, anomaly detection, RBAC, and remediation roadmaps for executives and engineers established a repeatable OT risk-management process.
Predictive optimization — liquid cooling loops

15–18%
less energy
OT
network segmented
Read the full case study
A hyperscale facility’s PLC/BMS lacked predictive control. Auragine added telemetry aggregation, anomaly detection, and predictive flow optimization that adjusts pump speeds and valve positions from server load, ambient temperature, and history — with the OT network segmented and secured.
Hybrid free-cooling optimization — cloud-edge data center

35%
less energy + water
60%
more free-cooling hours
Read the full case study
In a semi-arid climate with a limited water budget, manual switching between free, economizer, and chiller modes caused overcooling at night and excess water use at peak heat.
Predictive ambient monitoring, dynamic fluid-loop control, automated mode selection, and sustainability limits now switch cooling modes autonomously while the OT network is segmented with secure HMI access and anomaly alerts.